Type and color coding in accordance with DIN EN 60584-3
Other diameters and versions available on request
* Types C and D and their color coding are not subject to any official standard
Thermocouple type | Designation | | Outer D in mm | | Operating temperature of the cable | | Jacket material | | Color coding / polarity | |
K | TKK... | | 0,9 | | 300°C | | Polyimide | |  | |
K | TKT... | | 0,8 - 4,0 | | 250°C | | PTFE/PFA | |  | |
K | TKSi... | | 2,1 | | 200°C | | FEP/Silicone | |  | |
J | TJK... | | 0,9 | | 300°C | | Polyimide | |  | |
J | TJT... | | 2,5 -3,5 | | 250°C | | PTFE/PFA | |  | |
N | TNT... | | 2,5 - 3,5 | | 250°C | | PTFE/PFA | |  | |
E | TET... | | 2,5 - 3,5 | | 250°C | | PTFE/PFA | |  | |
T | TTT... | | 0,8 - 3,5 | | 250°C | | PTFE/PFA | |  | |
T | TTK... | | 0,9 | | 300°C | | Polyimide | |  | |
S | AST | | 2,5 - 3,5 | | 250°C | | PTFE/PFA | |  | |
R | ART.. | | 2,5 - 3,5 | | 250°C | | PTFE/PFA | |  | |
B | ABT... | | 2,5 - 3,5 | | 250°C | | PTFE/PFA | |  | |
C* | ACT... | | 2,5 - 3,5 | | 250°C | | PTFE/PFA | |  | |
D* | ADT... | | 2,5 - 3,5 | | 250°C | | PTFE/PFA | |  | |
| | | | | | | | |