Mineral-insulated heating conductors and mineral-insulated sheathed heating conductors with cold ends are used in a wide variety of applications and industries. They are associated with high expectations in terms of service life, reliability and safety. Particularly in application environments in vacuum or in the high-temperature range.
The function of the current connections is to separate the current-carrying inner core from the sheath so that the current is conducted in an insulated manner. Depending on the application and temperature range, the current connections for heatsealing bands are divided into stranded wire with direct connection and metallic/ceramic current connections.
CERAMIC POWER CONNECTOR KS POWER CONNECTOR WITH PIN/PIN | Â | Â | Â | ||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
KS-10 | 1,0 | 400°C, short-term 500°C | 10A |  | ![]() |
KS-15 | 1,5 | 400°C, short-term 500°C | 12A |  | |
KS-20 | 2,0 | 400°C, short-term 500°C | 17A |  | |
KS-30 | 3,0 | 400°C, short-term 500°C | 20A |  | |
 |  |  |  |  |  |
ÂCERAMIC POWER CONNECTOR KM4 -POWER CONNECTOR WITH M4 THREAD | Â | Â | Â | ||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
KM4-10 | 1,0 | 400°C, short-term 500°C | 10A |  | ![]() |
KM4-15 | 1,5 | 400°C, short-term 500°C | 12A |  | |
KM4-20 | 2,0 | 400°C, short-term 500°C | 17A |  | |
KM4-30 | 3,0 | 400°C, short-term 500°C | 20A |  | |
 |  |  |  |  |  |
ÂCERAMIC POWER CONNECTOR KM5 -POWER CONNECTOR WITH M5 THREAD | Â | Â | Â | ||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
KM5-10 | 1,0 | 400°C, short-term 500°C | 10A |  | ![]() |
KM5-15 | 1,5 | 400°C, short-term 500°C | 12A |  | |
KM5-20 | 2,0 | 400°C, short-term 500°C | 17A |  | |
KM5-30 | 3,0 | 400°C, short-term 500°C | 20A |  | |
 |  |  |  |  |  |
ÂCERAMIC POWER CONNECTOR KFG - POWER CONNECTOR WITH CERAMIC HEAD AND GRUB SCREW | |||||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
KFG-10 | 1 | 400°C | 10A |  | ![]() |
KFG-15 | 1,5 | 400°C | 12A |  | |
KFG-20 | 2 | 400°C | 20A |  | |
KFG-30 | 3 | 400°C | 30A |  | |
 |  |  |  |  |  |
ÂCERAMIC POWER CONNECTOR KD5 -MINIATURE POWER CONNECTOR D=5MM | Â | ||||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
KD5-10 | 1,0 | 200°C | 7A |  | ![]() |
KD5-15 | 1,5 | 200°C | 10A |  | |
 |  |  |  |  |  |
ÂCERAMIC POWER CONNECTOR KBK -POWER CONNECTOR WITH 2-PINS (DIAMETER 11MM) | Â | Â | |||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
KBK-15 | 1,5 | 400°C | 4A |  | ![]() |
KBK-20 | 2,0 | 400°C | 4A |  | |
 |  |  |  |  | |
ÂMETALLIC POWER CONNECTION L-HL POWER CONNECTION WITH PUSH/PULL FUNCTION | Â | Â | Â | ||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
LF.1-HL / LM.1-HL | 1,5 - 3,0 | 220°C | - |  | ![]() |
 |  |  |  |  | |
ÂDIRECT CONNECTION D5VA - 5MM WITH STRANDED WIRE | Â | Â | Â | ||
 |  |  |  |  |  |
Designation | For heatsealing band diameter in mm | Max. Operating temperature | Max. permissible current | ||
D5VA | 1,0 - 2,0 | 220°C | 15A |  | ![]() |
D7VA | 1,5 - 4,0 | 220°C | 25A |  | |
 |  |  |  |  |  |
Ceramic power connection:
Protect the ceramic components from external strong mechanical stress, vibration and impact! This could lead to hairline cracks and fractures and thus to failure.